Biological Safety Cabinets: Ensuring a Safe and Healthy Laboratory Environment

Introduction

Biological safety cabinets (BSCs) are essential equipment for laboratories working with biological agents and other potentially hazardous materials. They provide a barrier between the laboratory worker and the biological material, protecting both from exposure to potentially harmful substances.

According to the Centers for Disease Control and Prevention (CDC), an estimated 73,000 laboratory-associated infections (LAIs) occur each year in the United States. Of these, 14% are acquired in clinical laboratories, and 20% of LAIs are caused by biological agents like bacteria, viruses, and fungi. BSCs play a critical role in minimizing the risk of LAIs by providing a negative pressure environment that prevents the escape of hazardous aerosols from the cabinet.

Types of Biological Safety Cabinets

There are three main types of BSCs, classified based on their airflow patterns and level of containment:

Type A1: Provides the highest level of containment, with exhaust air passing through a HEPA filter before being recirculated back to the laboratory. This type is recommended for working with volatile or highly infectious agents.

biological safety cabinet

Type A2: Similar to Type A1, but designed for working with non-volatile infectious agents. The exhaust air is filtered through a HEPA filter before being released into the laboratory.

Biological Safety Cabinets: Ensuring a Safe and Healthy Laboratory Environment

Type B2: Provides a lower level of containment than Type A cabinets. The exhaust air is not HEPA-filtered but is passed through a downflow of HEPA-filtered air before being released into the laboratory. This type is suitable for applications such as microscopy, chemical dispensing, and animal handling.

Introduction

Selecting the Right BSC

The selection of the appropriate BSC for a particular laboratory depends on the specific hazards associated with the biological agents being handled. Factors to consider include:

  • Agent Risk Level: The higher the potential risk of the biological agent, the higher the level of containment required.
  • Volume of Material Handled: The amount of biological material being handled will determine the size of the BSC needed.
  • Laboratory Size and Layout: The BSC should be appropriately sized for the laboratory and fit comfortably within the workflow.
  • Maintenance and Certification Requirements: BSCs require regular maintenance and certification to ensure optimal performance. These factors should be considered when making a purchasing decision.

Using Biological Safety Cabinets

Proper use of BSCs is crucial for their effectiveness in protecting laboratory workers. Here is a step-by-step approach:

  1. Personal Protective Equipment (PPE): Wear appropriate PPE such as gloves, lab coats, and respirators when working in the BSC.
  2. Prepare the Work Area: Decontaminate the BSC work surface with 70% ethanol or another appropriate disinfectant.
  3. Transfer Materials: Bring only essential materials into the BSC. Transfer materials carefully, avoiding spills or contact with the cabinet sides.
  4. Position Materials: Place materials at least 4 inches from the front grill and away from the back wall of the cabinet.
  5. Maintain Airflow: Keep the sash lowered to the recommended level to maintain airflow.
  6. Work Slowly and Deliberately: Avoid sudden movements or excessive airflow disruption.
  7. Remove Materials: Remove materials carefully, avoiding contact with the cabinet sides or creating aerosols.
  8. Decontaminate: Decontaminate the BSC work surface and materials again before removing them.
  9. Turn Off the BSC: Allow the blower motor to run for a few minutes after use to clear the cabinet of any remaining aerosols.

Common Mistakes to Avoid

Common mistakes to avoid when using BSCs include:

  • Working with too much material or blocking the airflow
  • Touching the cabinet sides or placing materials on the back wall
  • Moving too quickly or creating excessive airflow turbulence
  • Improper decontamination of the BSC and materials
  • Working with materials that require a higher level of containment than the cabinet provides

Maintenance and Certification

Regular maintenance and certification are essential to ensure the proper functioning of BSCs. Maintenance typically includes:

  • Filter replacement (HEPA and ULPA filters)
  • Blower motor inspection and calibration
  • Airflow velocity measurements
  • Leak testing

BSC certification should be performed by a qualified professional every 12 months or as per manufacturer recommendations. Certification involves a thorough inspection and testing of the cabinet to ensure it meets performance standards.

FAQs

1. What is the difference between a Biosafety Level (BSL) and a BSC?

A BSL is a set of practices, procedures, and equipment used in a laboratory to minimize the risk of exposure to biological agents. A BSC is a specific type of equipment used within a BSL to provide primary containment.

2. What are the minimum airflow requirements for BSCs?

Type A1: 120 feet per minute (fpm) at the work opening
Type A2: 100 fpm at the work opening
Type B2: 90 fpm at the work opening

Biological Safety Cabinets: Ensuring a Safe and Healthy Laboratory Environment

3. How often should BSCs be inspected and certified?

Every 12 months or as per manufacturer recommendations.

4. Can BSCs be rendered ineffective?

Yes, BSCs can be rendered ineffective if they are not properly maintained, certified, or used. Common causes of reduced effectiveness include blocked airflow, leaks, and improper handling.

5. What should I do if a spill occurs in the BSC?

  • Immediately stop work and notify the supervisor.
  • Do not exit the cabinet until the spill has been cleaned up.
  • Decontaminate the spill area according to laboratory protocols.
  • If necessary, evacuate the laboratory and contact the biosafety officer.

6. How do I dispose of contaminated materials from the BSC?

Dispose of contaminated materials according to laboratory protocols. This may involve autoclaving, incineration, or chemical disinfection.

Call to Action

Biological safety cabinets are essential for protecting laboratory workers and the environment from biological hazards. By following the guidelines outlined in this article, you can ensure the safe and effective use of BSCs in your laboratory. Remember to consult with your institution's biosafety officer for specific guidance and regulations related to BSCs and laboratory safety.